NACE-CIP2-001 Exam is a rigorous test that requires candidates to have a strong understanding of the principles and practices of corrosion control and coatings. To be eligible to take the exam, candidates must have at least two years of experience in the field and have completed the NACE-CIP1 (Coating Inspector Level 1) Exam. Candidates who pass the NACE-CIP2-001 Exam will be awarded the Coating Inspector Level 2 certification, which is recognized by employers and industry professionals worldwide.

 

NEW QUESTION # 20
Inspection and Test plans are developed by referencing:

  • A. The Specification, Application Guidelines, 'Relevant Standards and Codes
  • B. The Specification, Safety Manual, Relevant Standards and Codes
  • C. The Specification, SDS, relevant Standards and Codes
  • D. The Specification, TDS, relevant Standards and Codes

Answer: D


NEW QUESTION # 21
An Inspection and Test Plan is required when:

  • A. When the Coating Applicator requests one
  • B. When the Inspector requests one
  • C. It is always required
  • D. When the Owner specifies one

Answer: C


NEW QUESTION # 22
When observing fabrication defects the NACE Inspector should:

  • A. Write an NCR and call the fabricator
  • B. Stop the job immediately
  • C. Require they be corrected prior to coating
  • D. Consult the specification to determine how they should be treated

Answer: D


NEW QUESTION # 23
When conducting inspections the Inspector should follow which standards:

  • A. Australian standards in Australia
  • B. ISO standards in Europe and Asia
  • C. The specified standards
  • D. NACE and SSPC standards in North America

Answer: C


NEW QUESTION # 24
NACE/SSPC Water Jetting standards are directly equivalent to ISO Abrasive Blast Standards:

  • A. True
  • B. False

Answer: B


NEW QUESTION # 25
Which is used to calibrate a pH meter?

  • A. Distilled water
  • B. Standard solvent solution
  • C. Deionized water
  • D. Standard buffer solution

Answer: D


NEW QUESTION # 26
The HATE adhesion tester uses

  • A. a special tape to apply pressure to the test dolly.
  • B. mechanical means only to apply pressure to the test dolly.
  • C. a hydraulic piston to apply pressure to the test dolly.
  • D. compressed air to apply pressure to the test dolly.

Answer: C


NEW QUESTION # 27
You are the NACE Level 2 Inspector with the final responsibility to prepare the final report for a very large structural steel shop project which has gone very well. It is due next week. The work has been ongoing for two years and several NACE Level 1 Inspectors have worked under your supervision throughout the project. You find you are missing one week of daily reports for the night shift from the very beginning of the project and despite your best efforts they are cannot found.
You FIRST preferred course of action is to:

  • A. Plainly state in your report that they are missing
  • B. Re-create the reports as not much was going on during night shift anyway
  • C. Use creative writing to cover over the fact they are missing
  • D. Do not complete your report until they can be found

Answer: A


NEW QUESTION # 28
When ASIN D 3363 is specified the Inspector must:

  • A. Record the percentage of failure
  • B. Record the two end points identified in the standard
  • C. Record the highest value attained
  • D. Use the correct solvent

Answer: B


NEW QUESTION # 29
Surface preparation methods for Non-ferrous metals are:

  • A. Specific for each type of Non-ferrous metal
  • B. The same for all Non-FetT0us metals
  • C. The same as for Ferrous metals
  • D. Not required

Answer: A


NEW QUESTION # 30
The primary purpose of Fireproofing coatings are to provide:

  • A. Preferential fuel for the fire
  • B. Explosion resistance
  • C. fire extinguishing characteristics
  • D. Temporary protection for the structure

Answer: D


NEW QUESTION # 31
Steel shot grit contaminated with oil or grease used in a cetrifugal blast cleaning should be

  • A. run through the air wash separator.
  • B. washed with clean potable water prior to Use.
  • C. mixed with uncontaminated abrasive
  • D. disposed of properly.

Answer: D


NEW QUESTION # 32
Inspectors perform tests on linings that they may not perform on exterior coatings because

  • A. linings are more durable than coatings.
  • B. coatings are expected to degrade over time.
  • C. coatings are more durable than linings.
  • D. linings protect the contents and the container.

Answer: D


NEW QUESTION # 33
Antifouling coatings are regulated by international treaties.

  • A. True
  • B. False

Answer: A


NEW QUESTION # 34
Generally for safety considerations, waterjetting hose connections use

  • A. an oil/water separator.
  • B. filters.
  • C. a long wand.
  • D. a whip-lock device.

Answer: D


NEW QUESTION # 35
The standards defining surface cleanliness achieved by centrifugal blast cleaning are:

  • A. Comparable to air blast cleaning
  • B. The same as air blast cleaning
  • C. Slightly different to air blast cleaning
  • D. Different than air blast cleaning

Answer: B


NEW QUESTION # 36
You are working as an inspector in a galvanizing plant for the first time.
What are some of the hazards you need to be aware of:

  • A. Risk of skin
  • B. Risk of chemical exposure
  • C. Risk of acid or caustic splashes
  • D. a), b), and c)

Answer: D


NEW QUESTION # 37
......


To be eligible to take the NACE-CIP2-001 exam, candidates must have a minimum of two years of experience in the coatings and corrosion prevention industry. Candidates who pass the exam will receive a certification from NACE, which is recognized globally as a symbol of expertise and excellence in the field of coating inspection.


NACE-CIP2-001 exam is a comprehensive exam that covers a wide range of topics related to coating inspection. NACE-CIP2-001 exam includes questions on coating types, surface preparation, application methods, and inspection techniques. Coating Inspector Level 2 certification is designed to ensure that coating inspectors have the knowledge and skills needed to perform their job effectively. Coating Inspector Level 2 certification is recognized in the industry as a standard for coating inspectors, and it is highly sought after by companies that require coatings inspections.

 

Test Engine to Practice NACE-CIP2-001 Test Questions: https://www.itcertmagic.com/NACE/real-NACE-CIP2-001-exam-prep-dumps.html

NACE-CIP2-001 Real Exam Questions Test Engine Dumps Training With 100 Questions: https://drive.google.com/open?id=14AfZfLLH9_DVXuPBNoU7fnD8C1iQz7-D