Best Quality Nutanix NCP-5.15 Exam Questions ITCertMagic Realistic Practice Exams [2021]
Critical Information To Nutanix Certified Professional - Multi cloud Infrastructure Pass the First Time
Retake Policies of Nutanix NCP-5.15
If an applicant fails an evaluation on the first try, two further attempts are permitted. Between attempts, there is a waiting time of seven days. These are compensated for separately as in the first attempt, and Nutanix advises giving ample time to be adequately trained to optimize the chances of success. Note: After three tries, you will not be able to take the 60 days examination after which you can send an e-mail to University. Nutanix advises that you use the time to evaluate this guide and its relevant sources closely and/or take the training prescribed.
For more info read reference:
Nutanix NCP 5.15 leaning site Nutanix NCP 5.15 resources
NEW QUESTION 109
Which change can be made on a cluster with software-based Data-at-Rest Encryption enabled?
- A. Deploy an additional Native KMS Server
- B. Change Native KMS to External KMS
- C. Enable encryption for a VM
- D. Disable encryption on the cluster
Answer: B
Explanation:
Reference:
https://next.nutanix.com/blog-40/security-with-simplicity-encryption-for-your-data-with-1-click-28225
NEW QUESTION 110
An administrator has observed that when an all- AHV host restarts unexpectedly one VM it hosts does not restart as expected.
Which cluster on VM configuration explains this behavior?
- A. Affinity for the VM is set for only the host that rebooted
- B. Nutanix Guest Tools are not installed on the VM
- C. No other all-flash nodes have capacity to host the VM
- D. VM high availability is not enabled
Answer: A
NEW QUESTION 111
What is the function of the virbr0 bridge on AHV?
- A. To carry all traffic between the user VMs and the upstream network.
- B. To carry management and storage communication between user VMs and AHV host.
- C. To carry storage communication between the guest VMs and the CVM
- D. To carry management and storage communication between user VMs and the CVM.
Answer: B
Explanation:
http://www.vstellar.com/2019/01/10/ahv-networking-part-1-basics/#:~:text=AHV%20Network%20Architecture&text=virbr0%20is%20an%20internal%20switch,virbr0)%20have%20IP%20address%20192.168.
NEW QUESTION 112
How should an administrator make sure that the is always up to date and upgraded to the latest version?
- A. From the Life Cycle Management page in Prism Central, click Perform Inventory every morning
- B. From the Life Cycle Management page in Prism Central, click Perform Inventory, then edit settings and click the Enable LCM Auto Inventory checkbox
- C. From the Life Cycle Management page in Prism Element, click Perform Inventory, then edit settings and set LCM Auto Inventory to Daily
- D. From the Life Cycle Management page in Prism Element, click Perform Inventory, then edit settings and click the Enable LCM Auto Inventory checkbox
Answer: A
NEW QUESTION 113
An administrator needs to determine current CPU usage across multiple clusters Which method should the administrator use to get the information?
- A. prism central home +ad widgtes
- B. Prism central home manage dashboards.
- C. Prism central home
- D. Prism central explore clusters
Answer: C
NEW QUESTION 114
The Stargate service becomes unavailable on a single CVM on an AHV node. What is used to maintain I/O operations in the cluster?
- A. ha.py
- B. Hypervisor HA
- C. iSCSl redirector
- D. Route injection
Answer: C
NEW QUESTION 115
An administrator is reviewing performance of a core banking system that routinely has 20,000 concurrent users. During, business hours, the CPU on the applications servers runs at close to 100%. The administrator needs to determine if there is a performance issue specific to the app servers, the database servers, or all servers on the cluster.
Which metrics should the administrator review in Prism Analysis Graphs?
- A. Cluster IO, CPU, Memory and Database and App Server CPU
- B. Cluster IO, Network, Database and App Server CPU
- C. Cluster CPU and Memory Only
- D. Cluster IO, CPU, Memory, Network, App Server CPU
Answer: A
NEW QUESTION 116
Which two steps are the minimum requited to perform an upgrade of AOS and AHV using a manual software upload? (Choose two.)
- A. Select Upload AOS Base Software Binary from the Life Cycle Manager page in Settings enter downloaded tar.gz and metadata JSON.
- B. Download the AOS tar.gz and metadata JSON files from the support portal.
- C. Download the Foundation car.gz and metadata JSONfiles from the support portal.
- D. Select Upload AOS Base Software Binary from the Upgrade Software page in Settings enter downloaded tar. gz and metadata JSON.
Answer: B,D
NEW QUESTION 117
Which three upgrades should an administrator be able to perform using Lifecycle Management? (Choose Three)
- A. HBA Firmware
- B. AOS
- C. Hypervisor
- D. BIOS
- E. BMC
Answer: A,B,C
NEW QUESTION 118
An administrator wants to view the total IOPs, read & write IOPs on a single graph in prism Which type of chart on the analysis is capable of allowing this view?
- A. entity chart
- B. performance chart
- C. measurement charts
- D. metric chart
Answer: A
NEW QUESTION 119
An administrator needs to shut down and relocate a Nutanix cluster.
Which step should the administrator take after shutting down all guest VMs on the cluster?
- A. Execute the command: cluster restart_genesis on a CVM
- B. Put each host into maintenance mode
- C. Change the node and CVM IP addresses if necessary
- D. Execute the command: cluster stop on a CVM
Answer: D
NEW QUESTION 120
An administrator deploys two VMs running a mail server application on a Nutanix cluster. The memory and CPU usage of these VMs must be tracked over time.
How should the administrator monitor these metrics?
- A. Create a metric chart for CPU usage and memory usage, including both VMs.
- B. Monitor the VM statistics page for each VM, exporting the required metrics to a CSV file.
- C. Create an entity chart for each VM, including CPU usage and memory usage.
- D. Create an entity chart containing both VMs, including hypervisor CPU ready %and memory usage.
Answer: A
NEW QUESTION 121
An Administrator is working on a one-node ROBO cluster configurations
Which statement is true for this configuration?
- A. the minimum RPO 8 hours required
- B. Witness vm required to break cluster quoram
- C. Supported hardware is NX-1175-G5 and G6
- D. witness vm should be 8vcp and 20gb ram
Answer: C
Explanation:
Reference:
https://www.nutanix.com/blog/unlocking-the-roboedge-it-landscape-with-the-launch-of-nutanix-1-node-cluster
NEW QUESTION 122
An administrator needs to view and compare IOPs for VMs across multiple clusters.
Which two dashboards can the administrator use to find this information? (Choose two)
- A. Apps
- B. Planning
- C. Explore
- D. Analysis
- E. Home
Answer: D,E
NEW QUESTION 123
A cluster is configured for RF2. The data resiliency status field in Prism is Critical.
What is the state of the cluster?
- A. A drive has failed and the node needs to be rebooted.
- B. A drive has failed and successfully re-replicated the missing data.
- C. A drive has failed and is currently re-replicating the missing data.
- D. A drive has failed and the node is critically close to failure.
Answer: C
NEW QUESTION 124
What is Prism Central primarily used for?
- A. Data reduction configuration
- B. Multi-cluster network configuration
- C. Container creation
- D. Multi-cluster Single Sign On
Answer: D
NEW QUESTION 125
CPU utilization climbs above 90% on several VMs. This causes performance degradation for a business-critical application.
How can alerts be configured to notify the administrator before VM CPU utilization hits 90%?
- A. On the Alerts dashboard, ensure that the VM CPU usage alert is not set to auto-resolve.
- B. On a CVM, configure a cron job to run the VM CPU Check more frequently and email the result.
- C. On the Health dashboard, locate the VM CPU Check and lower the alert threshold below 90%.
- D. On a CVM, use ncli to set the VM CPU Check threshold for the critical VMs to a value below 90%.
Answer: A
NEW QUESTION 126
Which configuration should an administrator make in Prism to receive a summary of the alerts every 24 hours?
- A. Individual Alerts
- B. SNMP
- C. Syslog
- D. Email Digest
Answer: D
Explanation:
Explanation
https://portal.nutanix.com/page/documents/details/?targetId=Prism_Central_Guide-Acr_v4_6:mul_alerts_manag Prism Central allows you to configure the alert messages sent by . To configure alert settings, reporting rules, and message templates, do the following:
Note: Alert emails sent by Prism Central are in addition to any alert emails you might have configured on individual clusters through the Prism web console. You will receive email from both entities in this case.
Prism Central alert emailing is not enabled by default; you must explicitly enable it and specify the recipients (Nutanix customer support and/or supplied email addresses).
* Do one of the following:
* In the gear icon pull-down list of the main menu, select Alert Email Configuration.
* In the Alerts dashboard, click the Email Configuration button.
The Alert Email Configuration window appears.
* Click the Settings tab and do the following:
* Enable Prism Central to sent alert emails.
* Check the Email Every Alert box to send an email whenever the event occurs.
* Check the Email Daily Digest box to send a cumulative (24 hour) list of alerts once a day.
You can check one or both boxes. If neither box is checked, no alert emails are sent by Prism Central.
* Check the Nutanix Support box to send alert notification to Nutanix customer support.
* To send alert notifications to others, enter their email addresses in a comma separate list in the field below the Nutanix Support
* Click the Apply button to apply the changes and continue the configuration (or click the Save button to apply the changes and close the window).
The Connection Status section displays mail transport status information. In this example, an SMTP server is configured for mail service. Clicking the link opens the SMTP server settings window
NEW QUESTION 127
A VM user permanently deletes a directory on a guest VM. The Nutanix administrator has enabled Self-Services for this VM.
Which three steps must the administrator perform to restore the directory? (Choose Three)
- A. Copy the directory from the snapshot disk to the original VM disk
- B. Connect to the cloned VM and copy the directory to the source VM
- C. Create a clone of the VM from a previous snapshot and replace the original VM
- D. Launch the Nutanix SSR utility on the VM
- E. Select and mount the snapshot that contains the deleted directory
Answer: A,D,E
NEW QUESTION 128
Which two methods are valid for migrating a VM from a Nutanix vSphere cluster to AHV? (Choose two.)
- A. Cross-Hypervisor DR
- B. Nutanix Move
- C. Storage vMotion
- D. Live Migration
Answer: A,B
Explanation:
Reference: https://hyperhci.com/2019/08/29/cross-hypervisor-migration-to-from-nutanix-ahv/
https://next.nutanix.com/blog-40/migrate-your-vms-to-ahv-with-minimum-downtime-31786
NEW QUESTION 129
What policy would maximize throughput for the brO uplink of a host?
- A. Active-Backup with MAC pinning
- B. Route based on ip hash
- C. Active-Active
- D. Switch Dependent, Dynamic
Answer: C
NEW QUESTION 130
An administrator is trying to create an additional account on the Nutanix cluster in Prism Element but is unable to create new users.
- A. The administrator's account is assigned a Cluster Admin role.
- B. The OpenLDAP server was temporarily down for maintenance.
- C. The connection to Active Directory server is disconnected.
- D. The cluster has reached the minimum number of accounts.
Answer: A
NEW QUESTION 131
Refer to the exhibit.
System Non-Root Partition Usage shows a warning or critical alert The administrator needs to change the frequency of checks and alerts to respond more quickly.
Where in Prism Element should the administrator change the frequency of checks and alerts?
- A. Alerts Dashboard > Manage Checks > Schedule
- B. Alerts Dashboard > Manage Checks > Frequency
- C. Health Dashboard > Manage Checks > Schedule
- D. Health Dashboard > Manage Crocks > Frequency
Answer: B
NEW QUESTION 132
Refer to the exhibit.
System Non-Root Partition Usage shows a warning or critical alert The administrator needs to change the frequency of checks and alerts to respond more quickly.
Where in Prism Element should the administrator change the frequency of checks and alerts?
- A. Alerts Dashboard > Manage Checks > Schedule
- B. Health Dashboard > Manage Crocks > Frequency
- C. Health Dashboard > Manage Checks > Schedule
- D. Alerts Dashboard > Manage Checks > Frequency
Answer: C
NEW QUESTION 133
......
NCP-5.15 EXAM DUMPS WITH GUARANTEED SUCCESS: https://www.itcertmagic.com/Nutanix/real-NCP-5.15-exam-prep-dumps.html